doi:10.3808/jeil.202600176
Copyright © 2026 ISEIS. All rights reserved
Assessment of Seasonal and Spatial Variation in Ground Water Quality of Hyderabad, India
Abstract
Water quality assessment is a critical component of sustainable water supply systems and plays a pivotal role in achieving the Sustainable Development Goals related to safe drinking water and public health. Although numerous studies have evaluated ground- water quality at regional and watershed scales, limited attention has been given to systematic assessment of groundwater quality within institutional campuses, where borewell water serves as the primary source of domestic water supply for a large resident population. Furthermore, seasonal variations in groundwater quality and the effectiveness of treated drinking water systems in such settings remain inadequately investigated, creating uncertainty in long-term water quality management and public health protection. Therefore, the pre- sent study evaluates the spatial and seasonal variability of groundwater quality across the bore wells of Maulana Azad National Urdu University (MANUU) campus, Hyderabad, which supports the domestic water demand of approximately 4,500 students and staff members. Key physicochemical parameters including pH, total hardness, total dissolved solids (TDS), Fluoride, Nitrate, electrical Conductivity, Tem- perature, Turbidity, and Specific Gravity were analyzed and compared with Bureau of Indian Standards (BIS) and World Health Organi- zation (WHO) standards. Results indicate that the majority of borewell samples exceeded the permissible limits for total hardness and TDS, with pronounced spatial and seasonal variability across the campus. Notably, TDS and total hardness increased significantly during the monsoon season. Nitrate concentrations remained low (0 ~ 20 mg/L) across all samples, likely due to the absence of agricultural activity and associated fertilizer runoff within the campus. Analysis of reverse osmosis (RO) treated water revealed extremely low hard- ness and TDS, underscoring the need to maintain these parameters within optimal ranges to safeguard public health and improve filter longevity. Additionally, the absence of free residual chlorine in tap water samples raises concerns regarding microbial safety, emphasiz- ing the need for adequate disinfection prior to distribution. The findings highlight the importance of continuous water quality monitoring at the institutional and community scales. The study recommends the deployment of real-time water quality sensors to generate long-term datasets, enabling advanced analytics and machine-learning-based water quality indexing and classification. Such integrated monitoring and management strategies can significantly enhance sustainable water conservation practices, support evidence-based decision-making, and improve the resilience of urban water supply systems. Total hardness ranged from 333 to 1,383 mg/L while TDS varied from 387 to 816 mg/L. The average WQI values varied from 19.77 in pre-monsoon to 14.71 in monsoon and 22.24 in post monsoon indicating sea- sonal variation in WQI and improvement in water quality in monsoon.
Keywords: water quality, pH, total hardness, total dissolved solids, WQI
Supplementary Files:
Refbacks
- There are currently no refbacks.